RH 802
RH 802 is a dual channel vibration analyzer for vibration analysis and dynamic balancing purposes. This portable analyzer has functions including waveform recording, run up / coast down, cross phase analysis, bump test and balancing.
Technical Specifications
Analog Input | |
Channels | Ch 1: Vibration, Voltage
Ch 2: Vibration, Voltage or Tacho meter |
Transducer | Accelerometer, velocity, displacement, voltage transducer |
Signal range | +-21 V |
ADC | 24 bits |
Analog measurement | |
integration | To velocity and to displacement |
Sampling frequency | 256 Hz to 102.4 kHz |
Frequency range | 40 kHz (incase dual channel 20 kHz each) |
Dynamic range | 96 dB |
Precision | 1% (0.1 dB) |
Signal processing | |
Configuration | Sampling frequency, low pass, sampling length as user defined |
Spectral lines | 400, 800, 1600, 3200, 6400 and 12800 |
Sampling blocks | 1024, 2048, 4096, 8192, 16384 and 32768 |
Windowing type | Hanning and Rectangular |
Averaging | Linear and peak hold |
Averages | 1 to 128 |
Hardware | |
LCD | True color LCD, 320*240 pixels and contrast adjustable |
Keys | 22 |
Communication | USB 2.0 |
Storage | 1 GB |
iButton | DS1990A |
Battery | Rechargeable
Charge time: 4 hours Usage time: 10 hours |
Temperature | -10 to +50 0C |
Protection | IP65 |
Dimensions | 190*110*50 mm |
Weight | 600 grams |