RH 802

RH 802 is a dual channel vibration analyzer for vibration analysis and dynamic balancing purposes. This portable analyzer has functions including waveform recording, run up / coast down, cross phase analysis, bump test and balancing.

Technical Specifications

Analog Input
Channels Ch 1: Vibration, Voltage

Ch 2: Vibration, Voltage or Tacho meter

Transducer Accelerometer, velocity, displacement, voltage transducer
Signal range +-21 V
ADC 24 bits
Analog measurement
integration To velocity and to displacement
Sampling frequency 256 Hz to 102.4 kHz
Frequency range 40 kHz (incase dual channel 20 kHz each)
Dynamic range 96 dB
Precision 1% (0.1 dB)
Signal processing
Configuration Sampling frequency, low pass, sampling length as user defined
Spectral lines 400, 800, 1600, 3200, 6400 and 12800
Sampling blocks 1024, 2048, 4096, 8192, 16384 and 32768
Windowing type Hanning and Rectangular
Averaging Linear and peak hold
Averages 1 to 128
Hardware
LCD True color LCD, 320*240 pixels and contrast adjustable
Keys 22
Communication USB 2.0
Storage 1 GB
iButton DS1990A
Battery Rechargeable

Charge time: 4 hours

Usage time: 10 hours

Temperature -10 to +50 0C
Protection IP65
Dimensions 190*110*50 mm
Weight 600 grams