Professional hydrophone solutions for underwater sound measurement, hydro-acoustic research, pressure monitoring, cavitation analysis and acoustic testing across different operating environments.
Enquire About Hydrophones →Explore four hydrophone models designed for different measurement requirements. The product range includes spherical compact hydrophones, dynamic pressure transducers and a digital hydrophone with integrated sensing and measurement functionality.
A robust spherical compact hydrophone for absolute measurements of sound propagation in an actuating medium.
A dynamic pressure transducer for sound and pressure measurement in homogeneous media, including air and water.
A dynamic pressure transducer with integrated amplification, balanced output and support for long cable connections.
A digital hydrophone with an integrated sensing element and pre-installed measurement parameters.
The BC 311 is a robust spherical compact hydrophone designed for absolute measurements of sound spreading in an actuating medium.
The hydrophone offers directional characteristics across its geometry, with an angular range of 270° in the X-Z plane and 360° in the X-Y plane.
BC 311 can operate as a sound projector and can also measure sound spreading in liquids. It can be used during reciprocity calibration.
Its piezoelectric sensing element has a reversible effect: mechanical stimulation generates an electrical signal, while an alternating voltage applied to the sensing element produces mechanical oscillations.
| Parameter | Underwater Version | Threaded Version |
|---|---|---|
| Labelling | BC 311 | |
| Version | Underwater | Threaded |
| Nominal Voltage Sensitivity | 65 µV/Pa | 39 µV/Pa |
| Nominal Charge Sensitivity | 0.44 pC/Pa | 0.3 pC/Pa |
| Sensitivity Level (relative to 1V/µPa) | -204 dB | |
| Frequency Band | 3 to 100,000 Hz | |
| Maximum Measured Sound Pressure Range | 100 kPa | |
| Maximum Measured Attenuating Sound Pressure Range | Up to 10 MPa | |
| Limit Static Line Pressure | 60 MPa | |
| Capacity Exclusive of Cable | Minimum 6 nF | |
| Explosion-Proof Version | — | Upon request |
| Casing Material | Stainless steel | |
| Dimensions (Length × Casing Diameter) | 173 × Ø23 mm | 171 × Ø23 mm |
| Coupling Thread | — | M20 × 1.5 |
| Cable Standard Length | 10 m | 2 m |
| Maximum Cable Length | 250 m | |
| Cable Type | Coaxial, PVC coating, central wire, shielded, resistant to environment with sulfuric acid | |
| Cable Connection | BNC | |
| Measurement Operating Medium | Water, air, oil and oil products, natural gas | |
| Operating Medium Temperature | 0 to +60 °C | |
| Environment Air Temperature | -60 to +80 °C | |
Measurement of sound propagation in water.
Measurement of ultrasonic signals in liquid environments.
Measurement of noise in wet and polluted media.
Sound measurement in liquid and gas environments in laboratory and factory settings.
BC 312 hydrophones are dynamic pressure transducers with an even response curve throughout the observed frequency range in homogeneous media, including air, sea water and fresh water.
They are used to determine explosion pressure in a range up to 1,000 kPa, with pulse duration of 2–5 ms and time sensitivity of approximately 0.1 ms.
BC 312 is also used in hydro-acoustics for reading underwater signals and noise, measurement purposes and as a component of beamed receiver hydroacoustic antennas.
Versions can be supplied without an integrated amplifier. In this configuration, the hydrophone can be used as a sonar transmitter.
| Parameter | Underwater Version | Threaded Version |
|---|---|---|
| Designation | BC 312 | |
| Version | Underwater | Threaded |
| Nominal Sensitivity | 200 µV/Pa | 150 µV/Pa |
| Sensitivity Level (relative to 1V/µPa) | -192 dB | -194 dB |
| Frequency Band | 20 to 20,000 Hz | |
| Self-Noise, RMS* | 0.02 Pa | |
| Maximum Measured Sound Pressure Range | 50 kPa | |
| Limit Static Line Pressure | 60 mPa | |
| Output Direct Voltage Level | 10 to 13 V | |
| Power | IEPE (DeltaTron / ISOTRON) | |
| Supply Voltage | +(18 to 30) V | |
| Supply Current | 3 mA | |
| Explosion-Proof Version | — | Upon request |
| Casing Material | Stainless steel | |
| Dimensions (Length × Casing Diameter) | 173 × Ø23 mm | 171 × Ø23 mm |
| Coupling Thread | — | M20 × 1.5 |
| Cable Standard Length | 10 m | 2 m |
| Maximum Cable Length | 100 m | |
| Cable Outer Diameter | 10.2 mm | |
| Cable Type | Coaxial, PVC coating, central wire, screened, resistant to environment containing sulfuric acid | |
| Cable Plug | BNC | |
| Measurement Operating Environment | Water, air, oil and oil products, natural gas | |
| Operating Environment Temperature | 0 to +60 °C | |
| Environment Air Temperature | -60 to +80 °C | |
Source specification note: The BC 312 source lists the limit static line pressure as 60 mPa. This unit is reproduced exactly as supplied and should be confirmed with the manufacturer before technical use. The asterisk on self-noise is retained from the source.
The BC 313 is a dynamic pressure transducer with an even response curve throughout the complete frequency range observed in homogeneous media, including air, sea water and fresh water.
It is intended for hydro-acoustic applications, including measuring sound pressure levels in liquid media and observing cavitation processes.
The hydrophone uses a piezoceramic element as its signal transducer. Its integrated amplifier enables signal transmission through long submarine cables, including down to 1,000 m ocean depth as stated in the supplied product information.
Internal nodes are electrically insulated from the metal casing. Signal interference protection supports operation in water reservoirs with differing electrical potential and in environments with high electromagnetic fields.
| Parameter | Underwater Version | Threaded Version |
|---|---|---|
| Designation | BC 313 | |
| Version | Underwater | Threaded |
| Nominal Sensitivity* | 50 µV/Pa 500 µV/Pa 5,000 µV/Pa | |
| Sensitivity Level* (relative to 1V/µPa) | -206 dB -186 dB -166 dB | |
| Frequency Band | 20 to 20,000 Hz | |
| Maximum Measured Sound Pressure Range* (as per nominal sensitivity) | 50 kPa 10 kPa 1 kPa | |
| Limit Static Line Pressure | 4 MPa | 7 MPa |
| Self-Noise** (as per nominal sensitivity) | 0.2 Pa 0.1 Pa 0.01 Pa | |
| Supply Voltage (Bipolar) | ±10 to ±15 V | |
| Current Consumption | 20 to 30 mA | |
| Explosion-Proof Version | — | Upon request |
| Casing Material | Stainless steel | |
| Dimensions (Length × Casing Diameter) | 173 × Ø23 mm | 171 × Ø23 mm |
| Coupling Thread | — | M20 × 1.5 |
| Cable Standard Length | 10 m | 2 m |
| Maximum Cable Length | 1,000 m | |
| Cable Outer Diameter | 6 mm | |
| Cable Type | Coaxial with PVC coating, central wire, screened, resistant to environment containing sulfuric acid | |
| Cable Connection | End-piece with wires | |
| Measurement Operating Environment | Water, air, oil and oil products, natural gas | |
| Operating Environment Temperature | 0 to +60 °C | |
| Environment Air Temperature | -60 to +80 °C | |
Configuration and ordering notes: * Nominal sensitivity and related parameters are determined when placing an order. The default is 500 µV/Pa; 50 µV/Pa or 5,000 µV/Pa can be specified for special orders. ** Self-noise is referred to output in the frequency band from 10 Hz to the upper band limit.
The BC 314-M is a digital hydrophone with an integrated sensing element. Measurements can begin immediately after switching on because the measurement process does not require measurement-channel adjustments.
Essential measurement parameters are pre-installed in the gauge memory.
The digital transducer output contains measured pressure values, so additional processing of the results is not required according to the supplied product description.
| Parameter | Specification |
|---|---|
| Parameter Gauged | Instant values, RMS, peak Pa, kPa |
| Measuring Range | 100 kPa |
| Self-Noise, RMS* | 0.1 Pa |
| Frequency Band | 20 to 3,200 Hz |
| Type of Transducers Connected | Integrated piezo transducer |
| Tolerance Limit of Sound Pressure Range Gauging | 10% |
| Limit Measured Dynamic Pressure | 50 kPa |
| Limit Hydrostatic Pressure | 7 MPa |
| Data Output Frequency | 12,000; 8,000; 4,000; 2,000; 1,000; 500 Hz For non-instantaneous values: 10 Hz |
| Data Interface | CAN 2.0 |
| Device Power | 9 to 24 |
| Current Consumption at 12 V | Up to 50 mA |
| Reading Frequency Response | Available (diagnostics) |
| Sensing Element Integrity Check | Available (diagnostics) |
| Power Check | Available (diagnostics) |
| Synchronization | Precision Time Protocol (PTP) |
| Casing Material | Stainless steel |
| Dimensions (Length × Casing Diameter) | 171 × Ø23 mm |
| Coupling Thread | M20 × 1.5 |
| Cable Length | 2 m (standard) |
| Measurement Operating Environment | Water, air, oil and oil products, natural gas |
| Operating Environment Temperature | 0 to +60 °C |
| Environment Air Temperature | -60 to +80 °C |
Specification notes: * Self-noise is referred to output in the frequency band from 10 Hz to the upper band limit. The source lists device power as "9 to 24" without a unit; this has been retained without assuming a voltage unit.
Contact Flamboyant Solutions to discuss BC 311, BC 312, BC 313 and BC 314-M hydrophones for underwater acoustic measurements, pressure monitoring and hydro-acoustic applications.
Contact Our Team →